The box tamper output will be triggered if the panel box is opened.
Programming Example
Program output No. 2 to report open and close, with close HIGH and
open LOW:
It will be noted from Table 7 that output No. 2 is already assigned as
the alarm output. This condition first needs to be disabled from output
2 before a new condition may be assigned otherwise CLOSE, OPEN
and ALARM will all be programmed to Programmable Output 2. To do
this a [0] should be programmed into location 22.
The location for a close instruction is location 28. From Table 6 it will
be noted that a value of [7] programmed into this location will cause
output 2 to go high. This output will remain high until the appropriately
programmed value gives the instruction for this output to be set low.
It will be noted that location 29 corresponds to an open condition.
From Table 6 it will be noted that a value of [12] will drive output 2 low.
Therefore if a value of [12] is programmed into location 29 output 2 will
be set low on an open condition.
If an output is programmed as a strobe output, the output will follow
the sequence illustrated below.
Figure 6: Strobe Output Sequence
Similarly, a fire detect output follows the sequence illustrated overleaf.