46
www.inivos.com
INSTRUCTION MANUAL REVISION 4.0 APRIL 2020
HYDROGEN PEROXIDE ROOM DECONTAMINATION
TASK SEQUENCE APPROX DURATION
Location set up Check room has been manually cleaned and position room contents
Seal all ventilation outlets, smoke detectors, doors and windows
Change ProXcin™ refill if level indicated is low
Position process monitor outside of room
Connect main unit with process monitor
Seal remaining door and perform final checks
8 minutes
Vapour diusion Start cycle from process monitor outside the room Up to 60 minutes
Decontamination process N/A 30 minutes
Deactivation process N/A 60 minutes
Post-process
requirements
Check H2O2 levels are safe (1ppm) using a portable gas leak detector
Unseal doors and windows
Return process monitor to main unit and remove ProXcide™ equipment
Remove VentKits™ from ventilation outlets
Remove CapKits™ from smoke detectors
Return room to original layout
Approx. 5 minutes
5.6 Method summary