MD280/MD280N User Manual Product Information
- 23 -
Item Specifications
Input terminal
There are five digital input terminals, one of which can be used
as high-speed pulse input. There are two analog input
terminals. AI1 can be used only as voltage input, while AI2 can
be used as voltage or current input. (It can be selected to
keyboard potentiometer input via the jumper.)
Output
terminal
Two digital output terminals
One relay output terminal
One analog output terminal (can be expanded to two), with
optional 0//4mA to 20mA or 0/2V to 10V. It can realize the
output of such physical parameters as setting frequency and
output frequency,while via FM to output 0kHz to 50kHz
square-wave signal. DO3 can also be set to open-collector
output. (AO, FM, DO3 share a channel, making a distinction
via the function selection.)
Display
and
Keyboard
Operation
LED display
The machine has the LED keyboard,and realize parameter
settings, status monitoring function
Protection
function
It can implement power-on motor short-circuit detection,
input/output phase loss protection, over current protection,
over voltage protection, under voltage protection, overheating
protection and overload protection.
Others
Optional parts
Optional external keyboard(which has two selection ,one is
with the potentiometer,the other is without the potentiometer),
braking components and external keyboard cable,etc.
Using place
Indoor, and be free from direct sunlight, dust, corrosive gas,
combustible gas, oil smoke, vapor, drip or salt.
Altitude 1000m, derated when above 1000m
Ambient
temperature
-10 ć Celsius to +40 ć Celsius (Derated when used in the
ambient temperature of 40 ć Celsius to 50 ć Celsius)
Humidity Less than 95%RH, without condensing
Environment
Vibration Less than 5.9 m/s
2
(0.6g)