Function Parameter Table MD280/MD280N User Manual
- 70 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
frequenc
y
F0-05
Frequen
cy
source
upper
limit
0:Numerical value setting (F0-06)
1˖AI1
2˖AI2
3˖PULSE setting (DI5)
1 0 ƾ
F0-06
Frequen
cy upper
limit
setup
0.00Hz to maximum frequency
(F0-04)
0.01Hz 50.00Hz ƿ
F0-07
Frequen
cy upper
limit
setup
0.00Hz to frequency upper limit
˄F0-06˅
0.01Hz 0.00Hz ƿ
F0-08
Speed-u
p/speed-
down
time unit
0: s (second)
1: m (minute)
1 0 ƾ
F0-09
Speed-u
p time 1
0.00s(m) to 300.00s(m) 0.01s(m)
Model
dependent
ƿ
F0-10
Speed-d
own time
1
0.00s(m) to 300.00s(m) 0.01s(m)
Model
dependent
ƿ
F0-11
Carrier
frequenc
y
0.5kHz to 16.0kHz 0.1kHz
Model
dependent
ƿ
F0-12
Running
direction
0: Consistent direction
1: Reverse direction
1 0 ƿ
F0-13 Referen
0˖ Maximum frequency
1 0 ƾ
efesotomasyon.com