Function Parameter Table MD280/MD280N User Manual
- 72 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
frequenc
y source
Y
selection
at the
time of
overlap
F0-18
Frequen
cy
source Y
selection
0˖Main
1˖Main + auxiliary
2˖MainÅ>Auxiliary
3˖MainÅ> Main + auxiliary
4˖AuxiliaryÅ>Main + auxiliary
1 0 ƿ
F0-20
Auxiliary
frequenc
y source
digital
setup
offset
0.00Hz to Maximum frequency
F0-04
0.01Hz 0.00Hz ƿ
Group F1 Motor Parameters and V/F Control Parameters
F1-00
Motor
rated
power
0.2kW to 1000.0kW 0.1kw
Model
dependent
ƾ
F1-01
Motor
rated
voltage
0V to 480V 1V
Model
dependent
ƾ
F1-02
Motor
rated
current
0.1A to 6553.5A 0.1A
Model
dependent
ƾ
F1-03
Motor
rated
frequenc
y
0.01Hz to maximu frequency
˄F0-04)
0.01Hz
Model
dependent
ƾ