Function Parameter Table MD280/MD280N User Manual
- 76 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
25:Length counting input (DI5)
26:Length counting reset
27:Interchange of AI1 and AI2
settings
28: Switch the frequency source to
AI1 ˈ it is enabled only set
F0-18(frequency + selection)to
0.
29:DC brake at stop enabled
30:Keyboard command source
switching
31:Terminal command source
switching
32:Switch between the first motor
and the second motor
F2-05
DI
filtering
time
1 to 10 1 4 ƿ
F2-06
Terminal
comman
d mode
0: two-line mode 1
1: two-line mode 2
2: three-line mode1
3: three-line mode2
1 0 ƾ
F2-07
Terminal
UP/DO
WN
velocity
0.01Hz/s to 100.00Hz/s 0.01Hz/s 1.00Hz/s ƿ
F2-08
AI1
minimu
m input
0.00V to F2-10 0.01V 0.02V ƿ
F2-09 Corresp -100.0% to 100.0% 0.1% 0.0% ƿ