Description of Function Codes
MD380 User Manual
- 184 -
Function
Code
Parameter
Name
Setting Range Default
F7-03
LED display
running
parameters 1
0000–FFFF
7 6 5 4 3 2 1 0
Running frequency 1 (Hz)
Set frequency (Hz)
Bus voltage (V)
Output voltage (V)
Output current (A)
Output power (kW)
Output torque (%)
DI input status (V)
15 14 12 11 10 9 8
DO output status
AI1 voltage (V)
Count value
Length value
Load speed display
PID setting
13
AI2 voltage (V)
AI3 voltage (V)
If a parameter needs to be displayed during the running,
set the corresponding bit to 1, and set F7-03 to the
hexadecimal equivalent of this binary number.
1F