Function Code Parameter Name Setting Range Default
F9-47
Fault protection
action selection 1
Unit's digit (Motor overload, Err11)
00000
0: Coast to stop
1: Stop according to the stop mode
2: Continue to run
Ten's digit (Power input phase loss, Err12)
Same as unit's digit
Hundred's digit (Power output phase loss, Err13)
Same as unit's digit
Thousand's digit (External equipment fault, Err15)
Same as unit's digit
Ten thousand's digit (Communication fault, Err16)
Same as unit's digit
F9-48
Fault protection
action selection 2
Unit's digit (Encoder fault, Err20)
00000
0: Coast to stop
1: Switch over to V/F control, stop according to the
stop mode
2: Switch over to V/F control, continue to run
Ten's digit (EEPROM read-write fault, Err21)
0: Coast to stop
1: Stop according to the stop mode
Hundred's digit: reserved
Thousand's digit (Motor overheat, Err25)
Same as unit's digit in F9-47
Ten thousand's digit (Accumulative running time
reached)
Same as unit's digit in F9-47