MD380 User Manual Function Code Table
- 91 -
Function
Code
Parameter Name
Setting Range
Default Property
F4-33 AI curve selection
Unit's digit (AI1 curve selection)
321
Curve 1 (2 points, see F4-13 to
F4-16)
Curve 2 (2 points, see F4-18 to
F4-21)
Curve 3 (2 points, see F4-23 to
F4-26)
Curve 4 (4 points, see A6-00 to
A6-07)
Curve 5 (4 points, see A6-08 to
A6-15)
Ten's digit (AI2 curve selection)
Curve 1 to curve 5 (same as AI1)
Hundred's digit (AI3 curve
selection)
Curve 1 to curve 5 (same as AI1)
F4-34
Setting for AI less than
minimum input
Unit's digit (Setting for AI1 less
than minimum input)
000
0: Minimum value
1: 0.0%
Ten's digit (Setting for AI2 less
than minimum input)
0, 1 (same as AI1)
Hundred's digit (Setting for AI3
less than minimum input)
0, 1 (same as AI1)
F4-35 DI1 delay time
0.0–3600.0s
0.0s
F4-36 DI2 delay time
0.0–3600.0s
0.0s
F4-37 DI3 delay time
0.0–3600.0s
0.0s
F4-38 DI valid mode selection 1
Unit's digit (DI1 valid mode)
00000
0: High level valid
1: Low level valid
Ten's digit (DI2 valid mode)
0, 1 (same as DI1)
Hundred's digit (DI3 valid mode)
0, 1 (same as DI1)