MD380 User Manual Function Code Table
- 93 -
Function
Code
Parameter Name
Setting Range
Default Property
F3-13
Voltage source for V/F
separation
0: Digital setting (F3-14)
1: AI1
2: AI2
3: AI3
4: Pulse reference (DI5)
5: Multi-reference
6: Simple PLC
7: PID
8: Communication reference
The value 100.0% corresponds to
the rated motor voltage
0 ƿ
F3-14
Voltage digital setting for V/F
separation
0 V to rated motor voltage
0 V ƿ
F3-15
Voltage rise time of V/F
separation
0.0–1000.0s
It indicates the time for the
voltage to rise from 0 V to rated
motor voltage.
0.0s ƿ
F3-16
Voltage decline time of V/F
separation
0.0–1000.0s
It indicates the time for the
voltage to decline from rated
motor voltage to 0 V.
0.0s ƿ
F3-17
Stop mode selection upon V/
F separation
0: Frequency
and voltage
declining to 0 independently
1: Frequency decli
ning after
voltage declines to 0
0 ƿ