Function Code Table
MD380 User Manual
- 94 -
Function
Code
Parameter Name
Setting Range
Default Property
Group F4: Input Terminals
F4-00 DI1 function selection
0: No function
)RUZDUG581):'
5HYHUVH5815(9
:KHQ',WHUPLQDOVDUHDOORFDWHG
with functions 1 and 2, F4-11
must also be set.
3: Three-wire control mode
)RUZDUGMRJ)-2*
5HYHUVHMRJ5-2*
7HUPLQDO83
1 ƾ
F4-01 DI2 function selection
7HUPLQDO'2:1
8: Coast to stop
9: Fault reset (RESET)
581GLVDEOHG
([WHUQDOIDXOW12LQSXW
12: Multi-reference terminal 1
13: Multi-reference terminal 2
4 ƾ
F4-02 DI3 function selection
14: Multi-reference terminal 3
15: Multi-reference terminal 4
16: Terminal 1 for acceleration/
deceleration time selection
17: Terminal 2 for acceleration/
deceleration time selection
9 ƾ
F4-03 DI4 function selection
18: Frequency source switchover
83DQG'2:1VHWWLQJFOHDU
(terminal, operation panel)
20: Command source switchover
terminal 1
21: Acceleration/Deceleration
prohibited
22: PID disabled
23: PLC state reset
:REEOHGLVDEOHG
25: Counter input
26: Counter reset
12 ƾ
F4-04 DI5 function selection
27: Length count input
28: Length reset
29: Torque control prohibited
13 ƾ