4 Function and Application
- 25 -
4
Inverter
03 Device Control
04 Authority
05 System Set
Back Select18:00:02
Loc
Stop
• 06 System Control
Inverter
• 01 Parameter Copy
02 Update SOP
Back Select18:00:02
Loc
Stop
Inverter
• 01 Read Parameter
02 Write Parameter
Back Select
18:00:02
Loc
Stop
1) Read parameter
This operation shall read all parameters of the system.
Set the user-dened part of the le name before performing reading parameters. The user-dened part
consists of 5 digits. use
and to select the digit, and
/ to change the value (range: 0-9
and A-Z) of the digit. The format of the le name is as follows: Device name-5-digit user-dened part-time.
ipv
For example: Inverter--00002-0302134905.ipv, Where inverter is the device name, 00002 is the user-
dened part, 02 March, 13: 49: 05.
Press to read and copy the parameters after the le name is set. "Handle succeed" will display on
the interface after reading and copying parameter is nished. Specic reason will be displayed if reading
and copying parameter failed.
Figure 4-11 Read parameter
Inverter
01 Read Parameter
Back Select18:00:02
Loc
Stop
18:00:02
58%
Reading Parameter…
00
:
00
0 : 无功能
0 : 无功能
Parameter Copy
Succeed
18:00:02
44%
Reading Parameter…
00:02
Back OK18:00:
02
Loc
Input File Name
0 0 0 0 2
Back OK
• 02 Write Parameter
2) Write parameters
Different from reading parameters, there are two kinds of parameter write mode: "all copy mode" and
"non-motor parameter copy mode". All copy mode copies all the parameters except the communication
parameters. The non-motor parameter copy mode is tailored for parameters of certain parameter range.
Please check the user manual of the device.
The procedures of write parameters is as follows: