6 Parameter Description
-
179
-
circularly.
F-6: door open/close control
󶙓󶙓
respectively stand for the door open button and door close button. You can press the
PRG button to exit.
F-7: shaft auto-tuning command input
󶙓󶙓
󶙓󶙓󶙓󶙓
parameters in group FR; 2. Clear leveling adjustment parameters in group FR).
󶙓󶙓󶙓󶙓
if the conditions are met. Meanwhile, the display switches over to the F-0 menu. After
󶙓󶙓
󶙓󶙓
F-8: test function
󶙓󶙓
described as follows:
1
Hall call forbidden
2
Door open forbidden
3
Overload forbidden
4
Limit switches
disabled
6
Entering slip
experiment state
7
Manual test on UCMP
8
Manual test on braking
force
After the setting is complete, press the SET button. Then the 7-segment LEDs display
󶙓󶙓
exit, F8 is back to 0 automatically.
F-9: reserved
F-A: auto-tuning
After you enter the F-A menu, the LEDs display “0”. The setting range of F-A is 1 and 2,
as follows:
1
With-load Auto-
tuning
2
No-load auto-tuning
󶙓󶙓
the elevator enters the auto-tuning state.
󶍾
button again to start auto-tuning.
After auto-tuning is complete, the LEDs display the present angle for 2s, and then
switch over to the F-0 menu.
You can press the PRG button to exit the auto-tuning state.