6 Parameter Description
-
188
-
Function
Code
Name Setting Range Default Unit Property
F1-22
Auto-tuning
function
selection
Bit1 = 1, Bit2 = 0: Semi-automatic
angle-free auto-tuning
Bit1 = 1, Bit2 = 1: Full-automatic
angle-free auto-tuning
0 -
Bit1 and Bit2 is used to select the angle-free auto-tuning mode of the synchronous
motor.
Bit1 = 1, Bit2 = 0: Semi-automatic angle-free auto-tuning
󶍽
auto-tuning only during running at inspection speed. After auto-tuning is successful,
󶍽
󶍽
󶍾
enters the normal state.
Bit1 = 1, Bit2 = 1: Full-automatic angle-free auto-tuning
󶍽
auto-tuning during elevator running at inspection/normal speed. After auto-tuning is
󶍽
Function
Code
Name Setting Range Default Unit Property
F1-25 Motor type
0: Asynchronous motor
1: Synchronous motor
1 -
This parameter is used to select the motor type. The values are as follows:
0: Asynchronous motor
1: Synchronous motor
Group F2: Vector control parameters
Function
Code
Name Setting Range Default Unit Property
F2-00
Speed loop proportional gain
Kp1
0 to 100 40 -
F2-01 Speed loop integral time Ti1 0.01 to 10.00 0.60 s
F2-02 Switchover frequency 1 0.00 to F2-05 2.00 Hz
F2-03
Speed loop proportional gain
Kp2
0 to 100 35 -
F2-04 Speed loop integral time Ti2 0.01 to 10.00 0.80 s
F2-05 Switchover frequency 2 F2-02 to F0-06 5.00 Hz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE 3000 new Series and is the answer not in the manual?

Inovance Monarch NICE 3000 new Series Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE 3000 new Series
CategoryController
LanguageEnglish

Related product manuals