9 Description of Functions and Schemes
-
337
-
9.16.1 110 V Safety Circuit
The STO function takes the place of the RUN contactor, and is wired in the same way
as the RUN contactor. A safety relay is used to adapt the 24 V input of the STO card to
the 110 V power of common safety circuit.
110 V
N
Safety relay
24 V
COM
STO
Safety circuit
󶙽STO wiring under 110 V safety circuit
The RUN contactor is replaced with a safety relay and a STO card. The feedback termi-
nals DNS+ and DNS- of the STO card are connected to the DI terminals of the MCB, and
󶍿
9.16.2 24V Safety Circuit
If it is the 24 V safety circuit, the STO card can be directly connected to the safety
󶍾
24 V
COM
STO
Safety circuit
󶙽STO wiring under 24V safety circuit
The RUN contactor is replaced directly with a STO card.