9 Description of Functions and Schemes
-
321
-
9.12.1 Scheme 1
1 Wiring
Y1
M1
FX: shorting motor stator contactor SW: RUN contactor
NICE3000
new
CN7
Y1
M1
Y2
M2
Y3
M3
Y4
M4
Y5
M5
Y6
M6
R
S
T
External
power
supply
U
V
W
5 6
FX
1
2
3
4
5 6
FX
1
2
3
4
M
Motor
Y3
M3
110 VAC
FX
SW
X18
X18
24V
SW
110 VAC
󶙽Wiring of the independent shorting PMSM stator contactor
2 Parameters
The parameter setting in shorting PMSM stator mode is described in the following
table.
Function
Code
Name Value Description
F5-18 X18 function selection 30
Allocate X18 with "Input of shorting PMSM
stator feedback signal".
F5-28 Y3 function selection 3
Allocate Y3 with "Output of shorting PMSM
stator contactor feedback signal".
FE-33
Elevator function selection
2
-
Bit8 = 0: NC output contactor
Bit8 = 1: NO output contactor