EasyManua.ls Logo

Inovance Monarch NICE 3000 new Series - Group F6: Basic elevator parameters

Inovance Monarch NICE 3000 new Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Parameter Description
-
208
-
0: MCB digital input
1: CTB digital input
2: CTB analog input
3: MCB analog input
Function
Code
Name Setting Range Default Unit Property
F5-37
X25 function
selection
0: Invalid
4:Safety circuit signal
5: Door lock circuit signal
1
6: Door lock circuit signal
2
7: Door lock 1 shorting
8: Door lock 2 shorting
0 -
F5-38
X26 function
selection
0 -
F5-39
X27 function
selection
0 -
F5-40 X28 function selection 0 -
F5-37 to F5-40 are used to set signals input to heavy-current detection input terminals
X25 to X28. The values are as follows:
0: Invalid
4: Safety circuit signal
5: Door lock circuit signal 1
6: Door lock circuit signal 2
7: Door lock 1 shorting
8: Door lock 2 shorting

Table of Contents