6 Parameter Description
-
248
-
Function
Code
Name Setting Range Default Unit Property
FC-02 󶎀 0.50 to 10.00 1.00 -
FC-03
Overload pre-warning
󶎀
50 to 100 80 %
The FC-02 reference quantity is motor overload current. After detecting that the
output current reaches (FC-02 x Rated motor current) and the duration lasts the time
󶍾
motor overload.
The FC-03 reference quantity is motor overload current. After detecting that the
output current exceeds (FC-03 x Rated motor current) and the duration lasts the time
󶍾
Function
Code
Name Setting Range Default Unit Property
FC-04 Opposite door selection 0 to 3 0 -
Fb-00 is used to set the number of door machine(s).
Set it to 1 if there is only one door, and 2 if there are double doors.
FC-04 is used to set opposite door-related control function. The values are as follows:
0: Simultaneous control
1: Hall call independent, car call simultaneous
2: Hall call independent, car call manual control
3: Hall call independent, car call independent
Function
Code
Name Setting Range Default Unit Property
FC-11 11
th
fault code 0 to 9999 0 -
FC-12 11
th
fault subcode 0 to 65535 0 -
FC-13 11
th
fault month and day 0 to 1231 0 MM.DD
FC-14
11
th
fault hour and
minute
0 to 23.59 0 HH.MM
FC-15 21
st
fault code 0 to 9999 0 -
FC-16 21
st
fault subcode 0 to 65535 0 -
FC-17 21
st
fault month and day 0 to 1231 0 MM.DD
FC-18
21
st
fault hour and
minute
0 to 23.59 0 HH.MM
󶙼
FC-207 60
th
fault code 0 to 9999 0 -
FC-208 60
th
fault subcode 0 to 65535 0 -