6 Parameter Description
-
260
-
Function
Code
Name Setting Range Default Unit Property
E0-12 Torque current upon last fault 0.0 to 999.9 0 A
E0-13 Output voltage upon last fault 0 to 999.9 0 V
E0-14 Output torque upon last fault 0 to 200.0 0 %
E0-15 Output power upon last fault 0.00 to 99.99 0 kW
E0-16
Communication interference
upon last fault
0 to 65535 0
E0-17 Reserved 0 to 65535 0
E0-18 Input state 1 upon last fault 0 to 65535 0
E0-19 Input state 2 upon last fault 0 to 65535 0
E0-20 Input state 3 upon last fault 0 to 65535 0
E0-21 Input state 4 upon last fault 0 to 65535 0
E0-22 Input state 5 upon last fault 0 to 65535 0
E0-23 Output state 1 upon last fault 0 to 65535 0
E0-24 Output state 2 upon last fault 0 to 65535 0
E0-25 Car input state upon last fault 0 to 65535 0
E0-26
Car output state upon last
fault
0 to 65535 0
E0-27 Hall call state upon last fault 0 to 65535 0
E0-28 System state 1 upon last fault 0 to 65535 0
E0-29 System state 2 upon last fault 0 to 65535 0
 
···
E9-00 10
th
fault code 0 to 9999 0
 
E9-01 10
th
fault subcode 0 to 65535 0
E9-02 10
th
fault month and day 0 to 1231 0 MM.DD
E9-03 10
st
fault hour and minute 0 to 23.59 0 HH.MM
E9-04 10
st
fault logic information 0 to 65535 0
E9-05 10
st
fault curve information 0 to 65535 0
E9-06
Speed reference upon 10
st
fault
0.000 to 4.000 0 m/s
E9-07
Feedback speed upon 10
st
fault
0.000 to 4.000 0 m/s
E9-08 Bus voltage upon 10
st
fault 0 to 999.9 0 V
E9-09
Present position upon 10
st
fault
0.0 to 300.0 0 m
E9-10 Output current upon 10
st
fault 0.0 to 999.9 0 A