Loading...
9 Description of Functions and Schemes
-
315
-
3 Parameters
Function
Code
Name Setting Range Default
F6-12 󶍿 0 to F6-00 8
F6-59 Elevator function selection 1 Bit9: VIP function Bit9 = 1
F6-46 VIP function selection
󶍿
Bit1: VIP enabled by terminal
Bit8: Number of VIP car calls limited
0
Example
󶍿
1) 󶍿󶍿󶍿
Function
Code
Name Setting Range Value Remarks
F6-00
󶍿
elevator
F6-01 to 40 20
These two parameters are used to set
󶍿󶍿
elevator, determined by the number
of actually installed leveling plates.
F6-01
󶍿
the elevator
1 to F6-00 1
F6-12 󶍿 0 to F6-00 8 Set the 8
th
󶍿󶍿
FE-32
Elevator
function
selection 1
Bit9: VIP function Bit9 = 1 The VIP function is enabled.
F6-46
VIP function
selection
Bit8: Number
of VIP car calls
limited
-
Bit8 = 1: The elevator responds to only
one car call (the last one). Bit8 = 0:
The number of car calls is not limited.
2) Method of enabling VIP
󶍿
󶍿
to be set.
Function
Code
Name Setting Range Value Remarks
F6-46
VIP function
selection
Bit0: VIP enabled by
󶍿
Bit0 = 1
When there is a hall call at the VIP
󶍿
VIP enabled by terminal: The elevator enters the VIP state when the terminal for VIP
hall call becomes ON. In this mode, when the terminal for VIP hall call becomes ON,
󶍿
passengers. F6-46 Bit0 needs to be set.
Function
Code
Name Setting Range Value Remarks
FD-07
HCB: JP1
input
NO input:
1: Elevator lock signal
2: Fire emergency signal
󶍿
󶍿
󶍿
6: Door close button input
FD-07 = 4
1. These parameters are used to
set the functions of JP1 and JP2
on the HCB.
󶍽
󶍿
3. You can use either of JP1 and
JP2 for VIP input.
FD-08
HCB: JP2
input
FD-08 = 4
F6-46
VIP
function
selection
Bit1: VIP enabled by
terminal
Bit1 = 1
After the terminal for VIP hall
call becomes ON, the system
enters VIP running.