Appendix B Parameter Table
-
352
-
Function
Code
Name Setting Range Default Unit Property Page
F5-25 CTB input type 0 to 511 320 -
P204
to
206
F5-26 Y1 function selection
0: Disabled
1: RUN contactor
2: Brake contactor
3: Shorting door lock circuit contactor
󶍿
feedback
5: Door machine 1 open
6: Door machine 1 close
7: Door machine 2 open
8: Door machine 2 close
9: Brake and RUN contactors healthy
10: Fault state
11: Running state
12: Shorting motor stator contactor
13: Emergency evacuation automatic
switchover
14: System healthy
15: Emergency buzzer control
16: Higher-voltage startup of brake
17: Elevator running in up direction
18: Lamp/Fan running
19: Medical sterilization
20: Non-door zone stop
21: Electric lock
22: Non-service state
23: Emergency evacuation completed
25: Wire holder reset
26: Braking pipe short circuit output
󶍾
1 -
F5-27 Y2 function selection 2 -
F5-28 Y3 function selection 3 -
F5-29 Y4 function selection 4 -
F5-30 Y5 function selection 0 -
F5-31 Y6 function selection 0 -
F5-32 Communication status
CANbus and Modbus communication state
monitoring
- -
P200
to
P208
F5-33
F5-33 Program control
selection
󶍾
for Hong Kong
Bit4: Arrival gong disabled at night
Bit6: Door lock disconnected at inspection
switched over to normal running
Bit7: Fault code not displayed on the keypad
Bit8: Door open command canceled
immediately at door open limit
Bit9: Car stop and zero-speed torque holding
at abnormal brake feedback
0 -
F5-34 Terminal state display Monitoring of I/O terminals on MCB - -
F5-35 Terminal state display
Monitoring of I/O terminals on CTB, CCB and
HCB
- -
F5-36 Load cell input selection
0: MCB digital input
1: CTB digital input
2: CTB analog input
3: MCB analog input
1 -
F5-37 X25 function selection
0: Invalid
4: Safety circuit signal
5: Door lock circuit signal 1 (high-voltage
input detection point, checkable)
6: Door lock circuit signal 2 (high-voltage
input detection point, checkable)
7: Door lock 1 shorting
8: Door lock 2 shorting
0 -
F5-38 X26 function selection 0 -
F5-39 X27 function selection 0 -
F5-40 X28 function selection 0 -
Group F6: Basic elevator parameters
F6-00 󶍿 F6-01 to 40 9 -
P209
to
P211
F6-01 󶍿 1 to F6-00 1 -
F6-02 󶍿 F6-01 to F6-00 1 -
F6-03 󶍿 F6-01 to F6-00 1 -
F6-04 󶍿 F6-01 to F6-00 1 -
F6-05 󶍿 0 to 65535 65535 -
F6-06 󶍿 0 to 65535 65535 -