Appendix B Parameter Table
-
355
-
Function
Code
Name Setting Range Default Unit Property Page
F6-43 Attendant function selection
Bit0: Calls canceled after entering attendant
state
Bit1: Not responding to hall calls
Bit2: Attendant/Automatic state switchover
Bit3: Door close at jogging
Bit4: Automatic door close
Bit5: Buzzer tweeting at intervals in
attendant state
Bit6: Buzzer tweeting at intervals in
attendant state
Bit7: Car call button blinking to prompt
128 -
P220
to
P221
F6-44
Fire emergency function
selection
󶍾
emergency state
󶍾
emergency state
󶍾
emergency state
Bit6: Closing door by holding down the door
close button
Bit7: Reserved
Bit8: Door close at car call registering
󶍾
state
󶍾
󶍾󶍾
󶍾󶍿
Bit12: Not clearing car calls at reverse door
󶍾󶍾
Bit14: Opening door by holding down the
door open button
󶍾
󶍿
16456 -
F6-45
Emergency evacuation
function selection
Bit0-Bit1: Direction determine mode
(00: Automatically calculating direction; 01:
Load direction determining; 10: Direction of
󶍿
󶍿
(Otherwise, stopping at the nearest service
󶍿
Bit3: Reserved
Bit4: Compensation at startup (Whether to
be valid in emergency evacuation running)
Bit8: Emergency running time protection
Bit10: Emergency buzzer output
Bit12: Shorting stator braking mode
switched over to controller drive
Bit14: Emergency evacuation exit mode
(1: Exit at door close limit, 0: Exit at door
open limit)
Bit15: Shorting stator braking function
0 -
P222
to
P223
F6-46 VIP function selection
󶍿
Bit1: VIP enabled by terminal
Bit8: Number of VIP car calls limited
0 -
P223
F6-47 Blinking advance time 0.0 to 15.0 1.0 s
F6-48
Emergency evacuation
switching speed
0.010 to 0.630 0.010 m/s
F6-49 󶍿 0 to F6-00 0 -
P224
F6-50 󶍿󶍽 0 to 40 0 -
F6-51 Static current 0.00 to 655.00 0 A
F6-52 Program function selection
Bit2: CAN communication AFE support
Bit6: CAN communication leveling signal
Bit7: Door machine overheat detection
0 -