Appendix B Parameter Table
-
361
-
Function
Code
Name Setting Range Default Unit Property Page
Fd-31 Expansion board 1: Y1 output 0: Reserved
1: Door machine 1 open
2: Door machine 1 close
3: Door machine 2 open
4: Door machine 2 close
5: Brake and RUN contactors healthy (no
faults E37 and E36)
6: Fault state
7: Running monitoring
8: Synchronous motor self-lock output
9: Controller healthy
10: Buzzer tweet
11: Higher-voltage startup of brake
(continuous 4s)
12: Elevator running in up direction
13: Lamp/Fan running
14: Medical sterilization #
15: Non-door zone stop #
16: Electric lock #
17: Non-service state
18: Emergency evacuation completed
19: Fire emergency operation
20: Power failure emergency output
21: Door lock valid
22: Night output signal
0 -
P252
Fd-32 Expansion board 1: Y2 output 0 -
Fd-33 Expansion board 1: Y3 output 0 -
Fd-34 Expansion board 1: Y4 output 0 -
Fd-35 Expansion board 1: Y5 output 0 -
Fd-36 Expansion board 1: Y6 output 0 -
Fd-37 Expansion board 1: Y7 output 0 -
Fd-38 Expansion board 1: Y8 output 0 -
Fd-39 Expansion board 1: Y9 output 0 -
Fd-40 Expansion board 1: Y10 output 0 -
Fd-41 Expansion board 2: Y1 output 0 -
Fd-42 Expansion board 2: Y2 output 0 -
Fd-43 Expansion board 2: Y3 output 0 -
Fd-44 Expansion board 2: Y4 output 0 -
Fd-45 Expansion board 2: Y5 output 0 -
Fd-46 Expansion board 2: Y6 output 0 -
Fd-47 Expansion board 2: Y7 output 0 -
Fd-48 Expansion board 2: Y8 output 0 -
Fd-49 Expansion board 2: Y9 output 0 -
Fd-50 Expansion board 2: Y10 output 0 -
Group FE: Elevator function parameters
FE-00 Collective selective mode
0: Full collective selective
1: Down collective selective
2: Up collective selective
0 -