EasyManua.ls Logo

Inovance Monarch NICE 3000 new Series - Page 364

Inovance Monarch NICE 3000 new Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B Parameter Table
-
363
-
Function
Code
Name Setting Range Default Unit Property Page
FE-33 Elevator function selection 2
Bit1: Door open holding at open limit
Bit2: Door close command not output upon
door close limit
Bit4: Auto reset for RUN and brake contactor
stuck
Bit5: Slow-down switch stuck detection
Bit7: Forced door close
Bit15: Opposite door independent control
36 -
P255
to
P256
FF: Factory Parameters
FJ: Factory Parameters
Group FP: User parameters
FP-00 User password
0: No password
01 to 65535
0 -
P257FP-01 Parameter update
0: No operation
1: Restore default setting (except group F1)
2: Clear fault records
3: Clear shaft data
0 -
FP-02
󶍾
display
0: Invalid
1: Valid
0 -
FP-05 Contract No. 2 0 to 65535 0 -
P258
FP-06 Contract No. 1 0 to 65535 5555 -
Group Fr: Leveling adjustment parameters
Fr-00 Leveling adjustment function
0: Invalid
1: Enabled
0 -
P258
to
P259
Fr-01 Leveling adjustment record 1 0 to 60060 30030 mm
to to 0 to 60060 30030 mm
Fr-20 Leveling adjustment record 20 0 to 60060 30030 mm
Group E0: Details of last group of faults
E0-00 Last fault code 0 to 9999 0
P259
to
P260
E0-01 Last fault subcode 0 to 65535 0
E0-02 Last fault month and day 0 to 1231 0 MM.DD
E0-03 Last fault hour and minute 0 to 23.59 0 HH.MM
E0-04 Last fault logic information 0 to 65535 0
E0-05 Last fault curve information 0 to 65535 0
E0-06 Speed reference upon last fault 0.000 to 4.000 0 m/s
E0-07 Feedback speed upon last fault 0.000 to 4.000 0 m/s
E0-08 Bus voltage upon last fault 0 to 999.9 0 V
E0-09 Present position upon last fault 0.0 to 300.0 0 m
E0-10 Output current upon last fault 0.0 to 999.9 0 A
E0-11
Output frequency upon last
fault
0.00 to 99.99 0 Hz
E0-12 Torque current upon last fault 0.0 to 999.9 0 A
E0-13 Output voltage upon last fault 0 to 999.9 0 V
E0-14 Output torque upon last fault 0 to 200.0 0 %
E0-15 Output power upon last fault 0.00 to 99.99 0 kW
P261
E0-16
Communication interference
upon last fault
0 to 65535 0
E0-17
Encoder interference upon last
fault
0 to 65535 0
E0-18 Input state 1 upon last fault 0 to 65535 0
E0-19 Input state 2 upon last fault 0 to 65535 0
E0-20 Input state 3 upon last fault 0 to 65535 0
E0-21 Input state 4 upon last fault 0 to 65535 0
E0-22 Input state 5 upon last fault 0 to 65535 0
E0-23 Output state 1 upon last fault 0 to 65535 0
E0-24 Output state 2 upon last fault 0 to 65535 0
E0-25 Car input state upon last fault 0 to 65535 0
E0-26 Car output state upon last fault 0 to 65535 0
E0-27 Hall call state upon last fault 0 to 65535 0
E0-28 System state 1 upon last fault 0 to 65535 0
P260
E0-29 System state 2 upon last fault 0 to 65535 0

Table of Contents