2 Installation and Wiring
-
79
-
󶙽Parameter setting
Function
Code
Name Setting Range Value
F5-01 X1 function selection
01/33: Up leveling signal NO/NC
03/35: Door zone signal NO/NC
02/34: Down leveling signal NO/NC
04/36: Safety circuit feedback NO/NC
05/37: Door lock circuit feedback NO/NC
06/38: RUN contactor feedback NO/NC
07/39: Brake contactor feedback NO/NC
22/54: Shorting door lock circuit contactor feedback NO/NC
08/40: Inspection signal NO/NC
09/41: Inspection/emergency drive up signal NO/NC
10/42: Inspection/emergency drive down signal NO/NC
84/116: Emergency drive signal NO/NC
12/44: Up limit signal NO/NC
13/45: Down limit signal NO/NC
16/48: Up slow-down 1 signal NO/NC
17/49: Down slow-down 1 signal NO/NC
18/50: Up slow-down 2 signal NO/NC
19/51: Down slow-down 2 signal NO/NC
Others:
00: Invalid
11/43: Fire emergency signal NO/NC
14/46: Overload signal NO/NC
15/47: Full-load signal NO/NC
20/52: Up slow-down 3 signal NO/NC
21/53: Down slow-down 3 signal NO/NC
22/54: Shorting door lock circuit contactor feedback NO/NC
󶍾
24/56: Door machine 1 light curtain signal NO/NC
25/57: Door machine 2 light curtain signal NO/NC
26/58: Brake travel switch 1 NO/NC
27/59: Emergency evacuation signal NO/NC
28/60: Elevator lock signal NO/NC
29/61: Safety circuit 2 feedback NO/NC
30/62: Shorting PMSM stator feedback NO/NC
31/63: Door lock circuit 2 feedback NO/NC
32/64: Reserved
65/97: Door machine 1 safety edge signal NO/NC
66/98: Door machine 2 safety edge signal NO/NC
67/99: Motor overheat signal NO/NC
68/100: Earthquake signal NO/NC
69/101: Back door forbidden signal NO/NC
70/102: Light-load signal NO/NC
71/103: Half-load signal NO/NC
󶍿
76/108: Door 1 open input NO/NC
77/109: Door 2 open input NO/NC
78/110: Brake travel switch 2 input NO/NC
79/111: External fault input
󶍿
81/113: Door lock 1 shorting
82/114: Door lock 2 shorting
86/118: Door lock bypass input
󶙹/NC
Note: For the same signal, NC setting parameter = NO setting
parameter + 32
33
F5-02 X2 function selection 35
F5-03 X3 function selection 34
F5-04 X4 function selection 4
F5-05 X5 function selection 5
F5-06 X6 function selection 38
F5-07 X7 function selection 39
F5-08 X8 function selection 22
F5-09 X9 function selection 40
F5-10 X10 function selection 09
F5-11 X11 function selection 10
F5-12 X12 function selection 44
F5-13 X13 function selection 45
F5-14 X14 function selection 48
F5-15 X15 function selection 49
F5-16 X16 function selection 50
F5-17 X17 function selection 51
F5-18 X18 function selection 00
F5-19 X19 function selection 00
F5-20 X20 function selection 00
F5-21 X21 function selection 00
F5-22 X22 function selection 00
F5-23 X23 function selection 00
F5-24 X24 function selection 00

Table of Contents