- 112 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
FA-17 Present position 0.0 to 300.0 0 m
ā
FA-18 Output current 0.0 to 999.9 0 A
ā
FA-19 Output frequency 0.00 to 99.99 0 Hz
ā
FA-20 Torque current 0.0 to 999.9 0 A
ā
FA-21 Output voltage 0 to 999.9 0 V
ā
FA-22 Output torque 0 to 100 0 %
ā
FA-23 Output power 0.00 to 99.99 0 kW
ā
FA-24
Communication
interference
0 to 65535 0 -
ā
FA-26 Input state 1 0 to 65535 0 -
ā
FA-27 Input state 2 0 to 65535 0 -
ā
FA-28 Input state 3 0 to 65535 0 -
ā
FA-30 Input state 5 0 to 65535 0 -
ā
FA-31 Output state 1 0 to 65535 0 -
ā
FA-32 Output state 2 0 to 65535 0 -
ā
FA-33 Car input state 0 to 65535 0 -
ā
FA-34 Car output state 0 to 65535 0 -
ā
FA-35 Hall sate 0 to 65535 0 -
ā
FA-36 System state 1 0 to 65535 0 -
ā
FA-37 System state 2 0 to 65535 0 -
ā
FA-38
Maximum īoor running
time
0 to 200 0 s
ā
It is used to set the time for the elevator to run from the bottom īoor to the top īoor at normal speed. The smaller
of FA-38+10s and F9-02 is used as the threshold for motor running protection. If the time that the leveling signal
keeps unchanged exceeds the threshold, the system prompts fault E30 and stops running.
FA-46
Hall call communication
state 1
0 to 65535 (īoors 1 to 16) 0 -
ā
FA-47
Hall call communication
state 2
0 to 65535 (īoors 17 to 32) 0 -
ā
FA-48
Hall call communication
state 3
0 to 65535 (īoors 33 to 40) 0 -
ā
FA-50
Extension hall call
communication state 1
0 to 65535 (īoors 1 to 16) 0 -
ā
FA-51
Extension hall call
communication state 2
0 to 65535 (īoors 17 to 32) 0 -
ā
FA-52
Extension hall call
communication state 3
0 to 65535 (īoors 33 to 40) 0 -
ā
FA-58 Version display
0: No equipment room monitoring
1: Having equipment room
extension board
2: Having car extension board
0 -
ā
FA-59
Extension board software
version
0 to 65535 0 -
ā