4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F9-04 Clock: month 1 to 12
Current
month
MM
ā˜†
F9-05 Clock: day 1 to 31
Current
day
DD
ā˜†
F9-06 Clock: hour 0 to 23
Current
hour
HH
ā˜†
F9-07 Clock: minute 0 to 59
Current
minute
MM
ā˜†
F9-09
Accumulative running
time
0 to 65535 0 h
ā—
F9-11
High byte of running
times
0 to 9999 0 -
ā—
F9-12
Low byte or running
times
0 to 9999 0 -
ā—
F9-09 to F9-12 are used to view the actual accumulative running time and running times of the elevator.
Running times of the elevator = F9-11 x 10000 + F9-12.
F9-13
Maintenance notication
period
0 to 99 0 day
ā˜…
It is the forced maintenance notication function.
When this parameter is set to a non-zero value, this function is enabled, and the system starts to count the days.
If there is no power-off operation during the counting and the counted days reaches the value of this parameter,
the elevator enters the parking state and the system reports Err08, notifying that the elevator must be maintained
and cannot run.
Maintenance personnel need to power off and maintain the elevator, and then the system clears the value to 0
and starts counting again.
If this parameter is set to 0, this function is disabled.
Group FA: Keypad setting parameters
FA-00 Keypad display selection
0: Reversed display of physical
oor
1: Positive display of physical oor
2: Reversed display of hall call
oor
3: Positive display of hall call oor
3 -
ā˜†
FA-01 Display in running state 1 to 65535 65535 -
ā˜†
FA-02 Display in stop state 1 to 65535 65535 -
ā˜†
FA-03 Current encoder angle 0.0 to 359.9 0.0 Degree (°)
ā—
FA-05 MCB board software 0 to 65535 0 -
ā—
FA-06 Drive board software 0 to 65535 0 -
ā—
FA-07 Heatsink temperature 0 to 100 0 °C
ā—
FA-11 Pre-torque current 0.0 to 200.0 0 %
ā—
FA-12 Logic information 0 to 65535 0 -
ā—
FA-13 Curve information 0 to 65535 0 -
ā—
FA-14 Set speed 0.000 to 4.000 0 m/s
ā—
FA-15 Feedback speed 0.000 to 4.000 0 m/s
ā—
FA-16 Bus voltage 0 to 999.9 0 V
ā—