- 89 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F5-33 Terminal program control
Bit3: Elevator re emergency
requirement for Hong Kong
Bit4: Arrival gong disabled at night
Bit6: Door lock disconnected at
inspection switched over to normal
running
Bit7: Fault code not displayed on
the keypad
Bit8: Door open command
cancelled immediately at door
open limit
Bit9: Car stop and zero-speed
torque holding at abnormal brake
feedback
0 -
ā˜…
It is used to select the elevator functions. Each bit of the parameter denes a function, as described in the
following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F5-33 are described in the following table.
Bit Function Description Default
Bit3
Elevator re emergency requirement
for Hong Kong
If it is enabled, the re emergency functions in F6-44
applied to Hong Kong become enabled automatically.
0
Bit4 Arrival gong disabled at night
The arrival gong is disabled from 22:00 p.m. to 7:00
a.m.
0
Bit6
Door lock disconnected at inspection
switched over to normal running
The door lock is additionally disconnected once when
the inspection state is switched over to the normal
running state.
0
Bit7
Fault code not displayed on the
keypad
The keypad does not blink to display the fault code. 0
Bit8
Door open command cancelled
immediately at door open limit
The system immediately cancels the door open
command after receiving the door open limit.
0
Bit9
Car stop and zero-speed torque
holding at abnormal brake feedback
When the brake feedback is abnormal, the elevator
arrives at the door-zone position and stops. The door
keeps closed, and the system holds torque output
as long as possible. After the system is overloaded,
there is no torque output, and the elevator may fall in
this case. Be cautious of using this function.
0
F5-34 Terminal state display
Monitoring of I/O terminals on
MCB
- -
ā—
F5-35 Terminal state display
Monitoring of I/O terminals on
CTB, CCB and HCB
- -
ā—