- 88 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
It is used to monitor the state of CANbus communication with the CTB and Modbus communication with the HCB.
When you enter the menu of F5-32, the LEDs on the operation panel indicate the current HCB communication
state.
Figure 4-5 F5-32 communication state monitoring
Segment No. indicates the address of the HCB at
each floor for Modbus communication with the MCB.
CANbus communication state from strong to weak
Best
Interrupted
Monitoring CANbus
communication state
between the CTB and the MCB
Segment ON: communication normal
Segment OFF: communication abnormal
1
2
35
6
4
7
8
9
10
11
15
12
13
14
16
17
23
18
19
20
21
2226
27
28
29
24
25
30
31
For example, if the LEDs are shown as the following īægure, it indicates that Modbus communication of addresses
1, 5, 6, 7, 12, 15, 16, 18, 19, 21, 22, 23, 25, 26 and 27 is abnormal, and Modbus communication of other
addresses is normal. CANbus communication state displayed by the LED is 3, indicating normal communication.
Figure 4-6 Example of LED display indicating the communication state
1
2
35
6
4
7
8
9
10
11
15
12
13
14
16
17
23
18
19
20
21
2226
27
28
29
24
25
30
31