- 91 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F5-35 Terminal state display
1 2 3 4 5
A Door 1 light curtain Door open button Door 1 open output
Door open button
display
System light curtain
state 1
B Door 2 light curtain Door close button Door 1 close output
Door close button
display
System light curtain
state 2
C Door 1 open limit
Door open delay
button
Door lock signal
Door open delay
button display
Hall call elevator
lock input
D Door 2 open limit
Direct travel ride
signal
Door 1 open output Non-door zone stop
Hall call re
emergency input
E Door 1 close limit Attendant signal Door 2close output Reserved Full-load signal
F Door 2 close limit
Direction change
signal
Door lock signal Buzzer output Overload signal
G Full-load signal
Independent
running signal
Up arrival gong Reserved -
DP Overload signal
Fireghter
operation signal
Down arrival gong Energy saving sign -
F5-36 Load cell input selection
0: MCB digital input
1: CTB digital input
2: CTB analog input
3: MCB analog input
1 -
ā˜…
F5-37 X25 function selection
0: Invalid
4: Safety circuit signal
5: Door lock circuit signal 1
6: Door lock circuit signal 2
7: Door lock 1 shorting (front door)
8: Door lock 2 shorting (back door)
0 -
ā˜…
F5-38 X26 function selection 0 -
ā˜…
F5-39 X27 function selection 0 -
ā˜…
F5-40 X28 function selection 0 -
ā˜…
Group F6: Basic elevator parameters
F6-00 Top oor of the elevator F6-01 to 40 9 -
ā˜…
F6-01
Bottom oor of the
elevator
1 to F6-00 1 -
ā˜…
These two parameters are used to set the top oor and bottom oor of the elevator, determined by the number of
actually installed leveling plates.
F6-02 Parking oor F6-01 to F6-00 1 -
ā˜…
F6-03 Fire emergency oor F6-01 to F6-00 1 -
ā˜…
F6-04 Elevator lock oor F6-01 to F6-00 1 -
ā˜…
When the idle time of the elevator exceeds the value set in F9-00, the elevator returns to the parking oor set in
F6-02 automatically.
After the re emergency signal is active, the elevator returns to the re emergency oor set in F6-03.
F6-04 is used to set the elevator lock oor. In the automatic running state, if the elevator lock switch is turned on
or the set elevator lock time is reached, the elevator cancels all registered hall calls and responds to all registered
car calls, returns to the elevator lock oor, stops automatic running, and closes the lamp and fan in the car; after
the door closes, the elevator cancels hall call display.
F6-05
Service oors 1 (oors
1–16)
0 to 65535 65535 -
ā˜…