- 96 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-11 is used to select the elevator functions. Each bit of the parameter denes a function, as described in the
following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-11 are described in the following table.
Bit Function Description Default
Bit1
Disabling returning to
base oor for verication
The function of returning to base oor for verication due to large
deviation of the car position is disabled.
0
Bit2
Cancelling auto
sequential arrange of hall
call oor addresses to be
displayed
If the display of a oor in group FE is set to 1, the following oors
to be displayed are automatically arranged in the ascending order.
0
Bit5
Current detection valid at
startup for synchronous
motor
The controller performs output current detection when the
synchronous motor is started up. If the current is abnormal, the
output will be locked and the running will be forbidden.
0
Bit6
Reversing MCB lamp
output
After this function is enabled, the MCB lamp output logic is
reversed.
0
Bit7
Door open valid at
non-door zone in the
inspection state
In the inspection state, you can open/close the door by pressing
the door open/close button at the non-door zone.
0
Bit8
Door open and close once
after inspection turned to
normal
The elevator door opens and closes once after the system turns
from rst-time inspection to normal running.
1
Bit10
Buzzer not tweet upon re-
leveling
The buzzer inside the car does not tweet upon re-leveling. 0
Bit11 Super short oor function
The controller cannot perform shaft auto-tuning if the oor height is
less than 500 mm. After this function is enabled, shaft auto-tuning
can be performed normally.
0
Bit12 Fault auto reset The controller automatically resets the faults once every hour. 0
Bit13 E53 fault auto reset
When Err53 is reported, if the conditions of door open limit valid
and door lock release are satised, the controller resets Err53
automatically. A maximum of three times of auto reset is allowed.
1
Bit14
Up slow-down not reset
for super short oor
If this function is enabled, the up slow-down 1 signal does not
reset oor display. The down slow-down 1 signal still resets oor
display. This is valid only when the super short oor function is
enabled.
0
Bit15
Down slow-down not
reset for super short oor
If this function is enabled, the down slow-down 1 signal does not
reset oor display. The up slow-down 1 signal still resets oor
display. This is valid only when the super short oor function is
enabled.
0
F6-12 VIP oor 0 to F6-00 0 -
ā˜…
F6-12 is used to set the VIP oor.
F6-13 Security oor 0 to F6-00 0 -
ā˜…