3 Peripheral Devices and Options
-
112
-
3.3.1 List of Options
If any optional in the following table is required, specify it in your order.
󶙽Options of the NICE3000
new
Name Model Function
External braking
unit
MDBUN
It is provided for the models of 37 kW (F model 45 kW) and
above.
PG card
MCTC-PG-A2
It is used to adapt to the push-pull and open-collector
incremental encoders.
MCTC-PG-D
󶍽
encoder for the 5 V power supply.
MCTC-PG-E
It is used to adapt to the SIN/COS encoder-ERN1387/Weton
SC53.
MCTC-PG-F1
It is used to adapt to the absolute encoder (Endat:
ECN413/1313).
MCTC-PG-F2 Communication encoder (Weton EA53)
Car top board
(CTB)
MCTC-CTB
The MCTC-CTB is the car control board of the NICE3000
new
.
It has 8 DIs, 1 AI and 7 relay outputs (9 as non-standard
󶍾
simultaneously.
Hall call board
(HCB)
MCTC-HCB
󶍿
where the elevator is located and the running direction. It
can also be used as car display board.
Car call board
(CCB)
MCTC-CCB
The MCTC-CCB is another interface for passengers to
interact with the control system. It mainly collects the car
calls and outputs the call indicator state.
Group control
board (GCB)
MCTC-GCB-A
The MCTC-GCB is used together with the NICE3000
new
to
implement group control of up to 8 elevators.
I/O expansion
card
MCTC-KZ-G1
󶎀
more terminals can be provided by using MCTC-KZ-G1.
MIB MCTC-MIB-A
The MCTC-MIB-A is used to query information such
󶍿
and send the information to the monitoring room via
communication. Users can monitor and control the
elevator by using the PC installed with the monitoring
software in the monitoring room.
External LED
operation panel
MDKE
It is the external LED display and operation panel. It
provides the RJ45 interface.
Extension cable MDCAB
It is a standard 8-core network cable and can be connected
to MDKE and MDKE6. The cable length is 3 m in the
󶍾

Table of Contents

Other manuals for Inovance Monarch NICE-L-C-2003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE-L-C-2003 and is the answer not in the manual?

Inovance Monarch NICE-L-C-2003 Specifications

General IconGeneral
CategoryController
ModelNICE-L-C-2003
Output Voltage24V DC
Storage Temperature-20°C to 70°C
Protection LevelIP20
Humidity5% to 95% (non-condensing)