9 Description of Functions and Schemes
-
310
-
9.6 Running Test
1 Function description
The running test parameters are set to facilitate elevator commissioning and
maintenance, involving:
■
Car call test
■
Random running test
■
Running test with disabling certain functions (hall call, door open, overload, limit)
Before the running test at normal speed, check that the shaft is unobstructed, and the
safety circuit, door lock circuit and shaft switches are all normal.
2 Parameters
Group F7 parameters for MCB test
Function
Code
Name Setting Range Default
F7-00 0 to F6-00 0
F7-01 0 to F6-00 0
F7-02 0 to F6-00 0
F7-03 Random running times 0 to 60000 0
F7-04 Hall call forbidden
0: No
1: Yes
0
F7-05 Door open forbidden
0: No
1: Yes
0
F7-06 Overload function
0: Disabled
1: Enabled
0
F7-07 Limit function
0: Enabled
1: Disabled
0
Example
Description of parameter setting
completed.
■
and then press the SET button to save the setting. The elevator runs to the destination
■
F-8: test function
described as follows: