- 142 -
5 Troubleshooting
5
Fault Code Name Possible Causes Solution Level
Err42
Door lock
disconnected
during running
Subcodes 101, 102:
The door lock circuit
feedback is invalid
during the elevator
running.
Check whether the hall door lock and the car
door lock are in good contact.
Check whether the door lock contactor acts
properly.
Check the signal feature (NO, NC) of the
feedback contact on the door lock contactor.
Check whether the external power supply is
normal.
5A
Err43
Up limit signal
abnormal
Subcode 101: The up
limit switch acts when
the elevator is running
in the up direction.
Check the signal feature (NO, NC) of the up
limit switch.
Check whether the up limit switch is in good
contact.
Check whether the limit switch is installed at
a relatively low position and acts even when
the elevator arrives at the terminal oor
normally.
4A
Err44
Down limit signal
abnormal
Subcode 101: The
down limit switch acts
when the elevator is
running in the down
direction.
Check the signal feature (NO, NC) of the
down limit switch.
Check whether the down limit switch is in
good contact.
Check whether the limit switch is installed at
a relatively high position and thus acts even
when the elevator arrives at the terminal oor
normally.
4A
Err45
Slow-down
switch abnormal
Subcode 101: The
down slow-down
distance is insufcient
during shaft auto-
tuning.
Check whether the up and down slow-down
switches are in good contact.
Check the signal feature (NO, NC) of the up
and down slow-down switches.
Ensure that the obtained slow-down distance
satises the slow-down requirement at the
elevator speed.
4B
Subcode 102: The up
slow-down distance
is insufcient during
shaft auto-tuning.
Subcode 103: The
slow-down switch is
stuck or abnormal
during normal
running.
Subcode 106: The
up and down slow-
down switches 2 act
improperly in shaft
auto-tuning.
Check whether the up/down slow-down
switch 2 is wired correctly.
Check the signal feature (NO, NC) of the up
and down slow-down switches 2.
Subcode 107: The
up and down slow-
down switches 3 act
improperly in shaft
auto-tuning.
Check whether the up/down slow-down
switch 3 is wired correctly.
Check the signal feature (NO, NC) of the up
and down slow-down switches 3.

Related product manuals