- 97 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-13 is used to set the security oor of the elevator.
If the security signal is active or it is during the night security period, the elevator runs to the security oor rst
every time, opens and closes the door once, and then runs to the target oor.
The elevator can be made to stop at the security oor in the following two ways:
Fd-07/Fd-08 is set to 5/37 (Security signal). If the security signal is active, the elevator enters the security state.
The night security oor function is enabled (FE-32 Bit5 = 2), the elevator enters the security state from 22:00 p.m.
to 6:00 a.m.
F6-14
Start time of down
collective selective 1
00.00 to 23.59 00.00 HH.MM
F6-15
End time of down
collective selective 1
00.00 to 23.59 00.00 HH.MM
F6-16
Start time of down
collective selective 2
00.00 to 23.59 00.00 HH.MM
F6-17
End time of down
collective selective 2
00.00 to 23.59 00.00 HH.MM
F6-18
Start time of time-based
oor service 1
00.00 to 23.59 00.00 HH.MM
F6-19
End time of time-based
oor service 1
00.00 to 23.59 00.00 HH.MM
F6-20
Service oor 1 of time-
based oor service 1
0 to 65535 65535 -
F6-21
Service oor 2 of time-
based oor service 1
0 to 65535 65535 -
F6-22
Start time of time-based
oor service 2
00.00 to 23.59 00.00 HH.MM
F6-23
End time of time-based
oor service 2
00.00 to 23.59 00.00 HH.MM
F6-24
Service oor 1 of time-
based oor service 2
0 to 65535 65535 -
F6-25
Service oor 2 of time-
based oor service 2
0 to 65535 65535 -
F6-26 Peak 1 start time 00.00 to 23.59 00.00 HH.MM
F6-27 Peak 1 end time 00.00 to 23.59 00.00 HH.MM
F6-28 Peak 1 oor F6-01 to F6-00 1 -
F6-29 Peak 2 start time 00.00 to 23.59 00.00 HH.MM
F6-30 Peak 2 end time 00.00 to 23.59 00.00 HH.MM
F6-31 Peak 2 oor F6-01 to F6-00 1 -
F6-35 Service oor 3 0 to 65535 65535 -
F6-36
Service oor 3 of time-
based oor service 1
0 to 65535 65535 -
F6-37
Service oor 3 of time-
based oor service 2
0 to 65535 65535 -
F6-38 Elevator lock start time 00.00 to 23.59 00.00 HH.MM
F6-39 Elevator lock end time 00.00 to 23.59 00.00 HH.MM