- 98 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
The elevator can switch to the locked state in the following two ways:
F6-40 Bit5 = 1, to enable the timed elevator lock function.
F6-38 and F6-39 are used to set the elevator lock time period, during which the elevator is in locked state.
Fd-07 = 1/33, to enable the hall elevator lock switch
F6-40
Program control selection
1
Bit0: Disability function
Bit1: Soft limit function
Bit2: JP16 input used as back door
selection
Bit3: JP16 input used as the back
door open signal
Bit4: Opening only one door of
opposite doors under manual
control
Bit5: Timed elevator lock
Bit6: Manual door
Bit9: Disabling reverse oor
number clear
Bit10: Displaying next arriving oor
number
Bit11: Responding to car calls rst
Bit12: Car call assisted command
in single door used as disability
function
Bit13: Folding command used as
disability function and back door
function
Bit14: Car call command folding
Bit15: JP20 used for switchover to
back door
0 -