Intergas Heating Ltd 8
2.5 Technical Product Fiche according to CELEX-32013R0811, ANNEX IV
Supplier Intergas Heating Ltd
Building 94, Bay 1 Vantage Point
The Pensnett Estate
Kingswinford
West Midlands
DY6 7FS
Type designation Symbol Unit Combi Compact HRE
24/18 28/24 36/30 36/40
Seasonal space heating energy
efficiency class
- - A A A A
Heat rated output
(power)
P
rated
kW 18 23 27 41
Seasonal space heating energy
efficiency
η
S
% 93 93 93 92
Annual energy consumption Q
HE
GJ 55 69 80 125
Sound power level L
WA
dB 45 45 50 55
Maximum load profile - - L XL XL XL
Water heating energy efficiency class - - A A A A
Water heating energy efficiency η
WH
% 84 87 87 87
Annual electricity consumption AEC kWh 14 17 16 16
Annual fuel consumption AFC kWh 3173 4975 4952 4952
CAUTION
Please read all instructions before fitting this appliance.
This appliance is not intended for use of persons (including children) with diminished physical, sensory or
mental ability, or lack of experience and knowledge, unless supervised by, or instruction about the use of the
appliance by a person who is responsible for their safety.
The appliance and installation should every year be inspected by an qualified installer and cleaned when
necessary. See annual cleaning § 12.
The appliance can be cleaned with a damp cloth. Don’t use aggressive or abrasive cleaning- or solvent
products.

Table of Contents

Other manuals for Intergas Combi Compact HRE 28/24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intergas Combi Compact HRE 28/24 and is the answer not in the manual?

Intergas Combi Compact HRE 28/24 Specifications

General IconGeneral
Type-
Fuel typeNatural gas
Boiler systemCombi boiler system
Product colorWhite
Heater locationIndoor
Placement supportedVertical
Gas inspection labelCW, HRe, NZ, SV
Boiler type (NL label)HR
CW inspection label class4
HR inspection label class107
Efficiency107 %
Maximum power- W
Water flow (40 °C)12.5 l/min
Water flow (60 °C)7.5 l/min
Maximum operating pressure3 bar
Domestic Hot Water (DHW) flow- l/min
Weight and Dimensions IconWeight and Dimensions
Depth240 mm
Width450 mm
Height650 mm
Weight33000 g