64  Concord 4 User Manual 
If you  need more time to complete testing, restart the timer by pressing 8, 
code, 3. 
Check to see that all sensors have been tested by pressing *. Touchpads 
display a list of untested sensors. You will know that you have finished testing 
when touchpads display SENSOR TEST OK or ZONES ALL TESTED. 
4.  Disarm to Level 1 to exit test mode. 
Table 13: Sensor test 
Trip  a police panic alarm, fire alarm, 
and auxiliary panic alarm 
POLICE  OK, FIRE OK, 
AUXILIARY  OK, POLICE  PANIC 
OK, FIRE PANIC OK, 
AUXILIARY  PANIC  OK 
ZONES  nn OK, TOUCHPAD  nn 
OK 
Press and hold the Lock and Unlock 
buttons simultaneously for  3 seconds. 
ZONES  nn OK, TOUCHPAD  nn 
OK 
Press and hold the Star and Light 
buttons simultaneously for  3 seconds. 
AUXILIARY  OK, AUXILIARY 
PANIC OK 
Press and hold the appropriate  panic 
buttons for  3 seconds. 
ZONES  nn OK, SENSOR nn OK 
Open the secured door or window 
ZONES  nn OK, SENSOR nn OK 
Press and hold the test button until the 
system sounds transmission beeps 
ZONES  nn OK, SENSOR nn OK 
Avoid  the motion detector view  for 5 
minutes, and then enter its view. 
Zones  nn OK, SENSOR nn OK 
Rate-of-rise  heat 
detector 
Rub your hands together  until warm, 
and then place one hand on the 
detector for 30 seconds. 
ZONES  nn OK, SENSOR nn OK 
Tap  the glass twice, away from  the 
sensor. Wait at least 30 seconds 
before  testing again. 
Zones  nn OK, SENSOR nn OK 
Phone interface  and 
voice  module 
Activate a police panic by accessing 
the system using the phone and 
pressing 
*, *, *, *, *, *. 
Tap  the glass 3 or 4 inches from the 
sensor. 
ZONES  nn OK, SENSOR nn OK 
Apply an ice cube wrapped  in plastic 
to the sensor. Do not allow the sensor 
to get wet. 
ZONES  nn OK, SENSOR nn OK