2 PIR Camera Reference Manual
System structure
An Advisor Advanced system can have one ATS1238 wireless PIR camera
expander mounted inside of the panel housing, and connected to the MI bus.
See “ATS1238 expander” on page 4 for details.
The system with a wireless PIR camera expander can have up to 8 wireless PIR
cameras programmed.
Figure 1: System structure
Camera activation
The system with a wireless PIR camera expander can have up to 8 wireless PIR
cameras programmed. Each camera can be activated in case of the following
events:
• Activation of one of 4 assigned zones. Zones are assigned in menu “4.3.n.2
Pics by zone” on page 11.
In this case camera event type depends on the zone type. See “Camera
event types” on page 3.
• Activation of a condition filter. The event type is defined for the programmed
filter. See “4.3 Cameras” on page 10.
• Activation of a standard reporting event. See “4.3.n.4 Pics by rep ev” on page
12.
• User command.
• Remote request from configuration software.
The number and the quality of pictures taken depend on the camera event type.
See “Programming menus” on page 7 for details.