8 PIR Camera Reference Manual
Tamper alarms
Faults: Device faults and technical alarms
Custom type 1: User programmable type 1
Custom type 2: User programmable type 2
See also “Camera event typeson page 3.
2.2.2.n.4.09.1.1 Burglar settings
1>Pic amount
1
Enter the BA settings menu to configure picture settings for burglar alarms.
2.2.2.n.4.09.1.1.1 Pic amount
1 Pic amount
>1<
Set the number of pictures taken after an event of the selected type occurs.
Allowed range is 1 to 30. The delay between pictures is set in “2.2.2.n.4.09.1.1.2
Frame ratebelow.
2.2.2.n.4.09.1.1.2 Frame rate
2 Frame rate
>500 ms<
The menu defines a frequency of taking pictures on an event of the selected
type.
The menu is only available if “2.2.2.n.4.09.1.1.1 Pic amountabove value is
larger than 1.
The allowed values are 500 ms, 1 s, 5 s, 15 s, 60 s.
2.2.2.n.4.09.1.1.3 Pic quality
3 Pict quality
>QVGA<
The option defines resolutions of pictures taken upon an event of the selected
type. The following options are available:
QVGA: 320 x 240 pixels
VGA: 640 x 480 pixels
QVGA and VGA: Two pictures at once, one in low resolution, and one in high.
2.2.2.n.4.09.1.2 Fire settings
2.2.2.n.4.09.1.3 Panic settings
2.2.2.n.4.09.1.4 Medical settings
2.2.2.n.4.09.1.5 Tamper settings