EasyManua.ls Logo

Intermatic PE24VA - Trouble Shooting; Actuator Handle Oscillates; Actuator Motor Works, Valve Diverter Does Not Turn; Actuator Motor Does Not Turn

Intermatic PE24VA
6 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
ONE YEAR LIMITED WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it,
at its sole option, the unit free of charge. This warranty applies only to the original purchaser and is not transferable. This warranty does not apply to:
(a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unauthorized
repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product.
Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal rights and
you may have other rights that vary from state to state.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER
EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE
OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid
to the nearest authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty
is made by: Intermatic Incorporated/After Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000 http://www/intermatic.com
Problem Cause Solution
1. Actuator handle oscillates. a. Lack of valve seal lubrication. Lubricate valve.
b. Obstruction in valve body. Remove actuator and valve lid and
inspect.
2. Actuator motor works but a. Broken actuator shaft. Replace actuator.
the valve diverter does
not turn.
b. Broken valve diverter. Replace valve diverter.
c. Actuator is in manual position. Pull up on the handle white rotating
counterclockwise.
d. Actuator gear train is damaged. Replace Actuator.
3. Actuator motor does not turn. a No power to the actuator. Check voltage between black
(common) and red then white wires.
b. Toggle switch is in OFF position. Move toggle switch to AUTO position
1 or 2 as needed.
c. Motor has failed. Replace actuator.
d. Failed or broken switch. Replace switch.
e. Both cams in contact with their Check cam setting.
switches.
4. Actuator rotates in one direction but a. Broken or damaged switch. Replace switch.
not back again.
b. Bad connection(s). Check all connections.
c. Bad control relay switch. At the power source check the
operation of the control relay or
switch.
d. Broken wire. Check red and white wires.
5. Water inside Actuator. a. Damaged seals. Replace top lid and grease seals.
TROUBLE SHOOTING
INTERMATIC INCORPORATED
Spring Grove, Illinois 60081-9698 U.S.A.
www.intermatic.com
158--01453
PRINTED IN CHINA
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

Other manuals for Intermatic PE24VA

Related product manuals