iv EasyCoder PC4/PC41 Mobile Battery Unit Installation Instructions
Before You Begin
Before You Begin
is section provides you with safety information, technical support
information, and sources for additional product information.
Safety Summary
Your safety is extremely important. Read and follow all warnings and
cautions in this document before handling and operating Intermec
equipment. You can be seriously injured, and equipment and data can be
damaged if you do not follow the safety warnings and cautions.
Do not repair or adjust alone
Do not repair or adjust energized equipment alone under any circum-
stances. Someone capable of providing fi rst aid must always be present
for your safety.
First aid
Always obtain fi rst aid or medical attention immediately after an injury.
Never neglect an injury, no matter how slight it seems.
Resuscitation
Begin resuscitation immediately if someone is injured and stops breath-
ing. Any delay could result in death. To work on or near high voltage,
you should be familiar with approved industrial fi rst aid methods.
Energized equipment
Never work on energized equipment unless authorized by a responsible
authority. Energized electrical equipment is dangerous. Electrical shock
from energized equipment can cause death. If you must perform autho-
rized emergency work on energized equipment, be sure that you comply
strictly with approved safety regulations.
Battery pack disposal
e battery pack contains nickel/metal hydride (NiMH) cells which are
potentially dangerous to the environment. Check and follow local regula-
tions for disposal of nickel/metal hydride batteries. Do not disassemble
the battery pack and only recharge it with approved equipment from
Intermec.

Other manuals for Intermec EasyCoder PC4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PC4 and is the answer not in the manual?

Intermec EasyCoder PC4 Specifications

General IconGeneral
Resolution203 dpi
Power Requirements100-240 VAC, 50-60 Hz
Print MethodDirect Thermal
Max Print Width4.09 inches (104 mm)
Max Print Speed4 inches per second
Max Print Length39 inches
Media TypeRoll-fed, die-cut, continuous, fanfold, tags, tickets
Media Width1.0 - 4.65 inches
Media Thickness0.06 mm (0.00236 in) to 0.18 mm (0.00708 in)
InterfaceRS-232
Memory4 MB Flash, 8 MB SDRAM
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Humidity10 to 90% non-condensing