Do you have a question about the Intermec PC4 and is the answer not in the manual?
Print Technology | Direct Thermal |
---|---|
Print Resolution | 203 dpi |
Max. Print Width | 104.1 mm (4.1 in) |
Media Type | Labels, Tags, Tickets |
Connectivity | USB |
Print Speed | Up to 4 ips (101.6 mm/sec) |
Maximum Print Width | 4.1 in (104.1 mm) |
Supported Barcode Types | Code 3 of 9, Code 128, Interleaved 2 of 5, UPC-A, UPC-E, EAN 13, EAN 8, Codabar, PDF417, Data Matrix, QR Code, Micro PDF417, Aztec |
Power Supply | 100-240 VAC, 50-60 Hz |
Provides crucial safety guidelines and warnings for operating Intermec equipment.
Guides on establishing a connection and sending ESim commands using terminal software.
Explains the conventions and rules for constructing valid ESim commands.
Command to reset all printer parameters to their factory default settings.
Signals the printer to accept variable or counter data for form fields.
Temporarily suspends printing, finishing the current label and pausing the job.
Command used to print ASCII text strings on labels, with parameter options for position, rotation, and font.
Command for printing various standard bar code symbologies with detailed parameter options.
Defines automatic counters for sequential numbering applications like serial numbers.
Explains how the printer firmware manages error conditions and recovery processes.
Lists and explains commands used for managing printer error reporting and recovery.
Classifies errors by type (A-H), detailing features, generated codes, and recovery methods.
Explains text-based error messages and their corresponding codes for troubleshooting.
Provides detailed tables of error codes, types, descriptions, LED status, and serial responses.