Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 31
• A trailing arrow indicates that data continues on the next line.
• A leading arrow f indicates data continued from the previous
line.
• Brackets < > is an alternative method for writing unprintable
ASCII characters, for example <ACK> = ASCII 06 decimal.
ABCDE
99999
P1
^default - Restore Factory Defaults
Purpose: This command sets all parameters back to the factory default.
Syntax: ^default
Remark: This command returns the printer to its default setup when
necessary; for example, prior to updating firmware. See “Resetting to
Factory Default Settings” on page 14 for the default value of setup
parameters. After sending this command, wait at least two seconds
before sending any further commands to ensure the printer has fully
restarted.010
^@ - Reset Printer
Purpose: This command resets the printer.
Syntax: ^@
Remarks: The ^@ command resets the printer in the same way as a power off
followed by a power on.
\ “\\”
\code\ “\\ccde\\”
Printing Examples (continued)
Print Enter
Note: If a 7-bit character set is selected, the quotation marks “ ” are
not supported and all backslash \ characters are printed as entered.