EasyManua.ls Logo

Intermec PC4

Intermec PC4
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 57
QR Code Example
C - Counter
Purpose: Use this command to define one of maximum 10 automatic counters
used in consecutive numbering applications, such as serial numbers.
Counters can only be used in the Form Edit mode, and not in the
Direct mode.
Syntax: Cp
1
,p
2
,p
3
,p
4
,[p
5
,],“PROMPT”
.
C- Counter Parameter Descriptions
Parameter Description
p
1
Counter number (0-9).
p
2
Maximum number of digits for the counter
(0-29).
p
3
Field justification:
L = Left justification.
R = Right justification.
C = Center justification.
N = No justification.
p
4
Step value. Plus or minus sign followed by a
single digit (1-9):
+ Increase.
- Decrease.

Table of Contents

Related product manuals