Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 63
Example:
This example renders a box and orders the printer to print 4 copies. At
command ^A, the printing is paused and continued again at
command ^C.
X,0,0,10,20,40
P4
^A
^C
D - Density
Purpose: Use this command to select the print density.
Syntax: Dp
1
Remarks: The density command is used to control the energy to the printhead.
A number of factors affect the actual darkness of the printout:
Direct thermal printing or thermal transfer printing.
Print speed.
Different brands of direct thermal media.
Different combination between transfer ribbons and receiving face
materials.
Different ambient temperature and humidity.
The printed information may also require the density to be adjusted.
Typically, this applies to different bar code orientations and densities.
Refer to the tables in the pages that follow for recommended initial
settings.
D- Density Parameter Descriptions
Parameter Description
p
1
Density settings (0-15). Default is 10.
0 is the lightest printing and 15 is the darkest.