Chapter 4 — ESim Commands
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 95
UM
UM150000,2048,0,0,0,0,0,0,UI80,001
Now, insert a 256 MB CF card into the printer and
type:
UM150,249912,0,0,0,0,0,0,0,UI80,001
N - Clear Image Buffer
Purpose: Use this command to clear the image buffer before building a new
image. It also clears any error list that has not been presented.
Syntax: N
Remarks: The N command is essential when printing labels in Direct mode. It is
not necessary to use the N command before printing a form. The N
command must not be used inside a form in the Form Edit mode.
O - Option Select
Purpose: Use this command to enable or disable various sensors and the cutter.
Syntax: O[Sp,N[,D[,Cnnn|Cb]]]
.
O Command Parameter Descriptions
Parameter Description
S Enable reverse gap sensing.
N Disable label taken sensor.