Chapter 4 — ESim Commands
112 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
SA - Setup Adjust
Purpose: Use this command is to control the activation and storage of setup
commands and values.
Syntax:
SAp
1
.
Remarks: The SA command affects the following setup commands: R, r, D, j, J,
q, Q, S, Z, and SPC. The current SA value is stored in Flash memory
and printed on the test label.
Example:
This example shows how to ignore all setup commands within a form.
SA2
SA Command Parameter Descriptions
Parameter Description
p
1
Setup adjust value:
0 = All commands remain active and values are
saved when changed. The printer uses stored
setup values (default).
1 = All setup parameters are locked and
commands are ignored. The printer uses only
previously stored setup values.
2 = All setup commands within forms are
ignored.