Chapter 4 — ESim Commands
128 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
Remarks: After receiving this command, the printer automatically resets its
communication on the serial RS-232 communication port. There are
no such parameters for the USB port.
By default, the printer is set for 9600 baud, no parity, 8 data bits, 1
stop bit. XON/XOFF handshaking is always used. The printer sends
XOFF when an error occurs. RTS/CTS is not supported.
If the current communication setup is not known, it can be checked
by printing a test label, see Autosensing Mode” on page 10 for
more information on how to print a test label.
Example:
In this example, we are setting a 19,200 baud rate, odd parity, 7 data
bits, and 1 stop bit.
Y19,O,7,1
Z - Print Direction
Purpose: Use this command to select the print orientation
Syntax: Zp
1
.
p
3
Number of data bits:
7 = 7 data bits
8 = 8 data bits
p
4
Number of stop bits:
1 = 1 stop bit
2 = 2 stop bits
Y Command Parameter Descriptions (continued)
Parameter Description
Z Command Parameter Descriptions
Parameter Description
p
1
Print orientation:
T = Start printing from the top of image
buffer (default).
B = Start printing from the bottom of image
buffer.