Chapter 4 — ESim Commands
50 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
Example:
N
b10,20,C,1EC,x4,Y12,B,p40,210,0,F,“(01)938123456
78901|(10)ABCD123456(410)3898765432108”
P
EAN/UCC Command Example
b - DataMatrix
Purpose: The following DataMatrix specific options should append the general
part of the two-dimensional code command indicated by the
italicized characters, see “b - Two-Dimensional Bar Codes, General
Part” on page 46 for more information.
Syntax: bp
1
,p
2
,p
3
,[P
4
,DATA”]
Example:
N
b40,80,D,5,”123456789012345678901234567890123456
7890123456789012345678901234567890
(01)93812345678901
(10)ABCD123456(410)3898765432108
b DataMatrix Command Parameter Descriptions
Parameter Description
P
4
Narrow bar from 1-15
“DATA” Represents a fixed data field, maximum 125
characters long